High-voltage cable and switchgear
The cables and switches that move power at high voltage. Cable order books run far ahead of output, and switchgear waits are long.
judged, with a citation claimed, no citationNumber: papers, preprints and grants the feeds collected — unreviewed
Searched for “HVDC cable”, “high voltage cable”, “SF6-free switchgear”, “gas-insulated switchgear” in titles and abstracts.
43 collected items, newest first ↓Judged by hand ↓Who is active ↓
All stagesFundamental researchApplied / labPilot / demonstrationEarly commercialAt scaleNewestMost cited
Directory companies in this research
- Mitsubishi Electric6503 JP1 (Computed: Items per institution per bottleneck, counting each item once per institution named on it by the source; a company is matched to the directory only when every distinguishing word of both names agrees.) itemlatest 2026-09-30
- Hitachi6501 JPvia Hitachi1 (Computed: Items per institution per bottleneck, counting each item once per institution named on it by the source; a company is matched to the directory only when every distinguishing word of both names agrees.) itemlatest 2024-06-13
Named on a collected paper or grant, matched to the directory by the strict name rule. A company not in the directory, or spelled differently by the source, is not shown here.
Judged by hand
- Superconducting transmission cable
City-scale links have run for years as demonstrations; no routine procurement path exists.
Collected by the feeds
- X-Ray-Based Lightweight High-Performance Non-Destructive Defect Detection Method for High-Voltage Cables
Zhejiang University of Science and TechnologyZhejiang University of Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Enhanced dielectric performance of polypropylene for hvdc cable insulation via 4‑allyloxybenzil grafting for multiscale structural modulation
Impact Polypropylene Copolymer (IPC) is a promising candidate for HVDC cable insulation, yet the lack of rigorous, quantitative structure-property correlations limits its performance optimization. In this study, a functional monomer, 4-Allyloxybenzil (AOB), containing benzene…
Tianjin University of Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Synergistic effects of mechanical, electrical, and thermal stresses on XLPE insulation breakdown
Abstract High-voltage direct current (HVDC) cables are essential for the centralized transmission of power from offshore wind farms and large-scale onshore new energy bases. The DC breakdown strength of cross-linked polyethylene (XLPE) insulation, when subjected to…
Xi'an Jiaotong UniversityTebian Electric Apparatus (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Recognition of multiple defects and signal intensities from superimposed partial discharge sources in gas-insulated switchgear
This study addresses the problem of poor recognition accuracy when a partial discharge pattern contains two defective discharge sources. First, a representative pattern for each defect was constructed using a gas-insulated switchgear (GIS) from three different defects including…
National Taiwan University of Science and Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Research on the reliability assessment method for Gas Insulated Switchgear based on composite risk assessment model
Fault diagnosis in safety–critical industrial infrastructure is often hindered by the data scarcity of catastrophic failures and subjective uncertainty inherent in domain knowledge. To address these challenges, this paper proposes a novel Hybrid Knowledge-Data Fusion method via a…
Beihang UniversityChina Electric Power Research Institute
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Research on cable condition evaluation method based on multi-sensor information fusion
High-voltage cables undertake core power transmission tasks in urban power grids, and multi-dimensional distributed sensors collect electrical, temperature, vibration, and environmental monitoring data synchronously. The raw monitoring data suffer from inconsistent sampling…
Taiyuan Heavy Industry (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Applicability of SF6 Alternative Gas-insulated Switchgear
This article outlines the current state of international regulations on SF6 gas and the development and application of equipment using SF6-alternative gases, based on domestic and overseas trends related to SF6 alternatives. It then compares, in terms of the basic properties and…
Mitsubishi Electric (Japan)Mitsubishi Electric in the directory6503 JP
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Back Feeding Energization Transients in a 500 kV Gas-Insulated Switchgear: Field Tests and Electromagnetic Transient Analysis
The special back feeding energization process involves several stages, including tie-transformer energization, GIS-busbar energization, and no-load line energization. These operations can generate transient overvoltages and impose considerable stress on equipment insulation. To…
State Key Laboratory of Electrical Insulation and Power EquipmentXi'an Jiaotong University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Uncertainty Evaluation for Space Charge Measurement in a Full-Sized Cable
Space-charge measurement is increasingly used to evaluate internal field distributions in HVDC cables, making quantitative uncertainty assessment essential for testing applications. Using pulsed electro-acoustic measurements on a full-scale cable with polymer and aluminum…
Central Research Institute of Electric Power IndustryToyohashi University of Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- A load-aware design-screening and virtual-prototype simulation framework for a four-wheel-steered chassis used in confined high-voltage cable handling
State Grid Corporation of China (China)
Applied / lab · Says "prototype".From OpenAlex · not yet reviewedDOIPDF
- Relationships of Multiphase Structure with Flexibility and DC Insulation Performance in Impact-Resistant Polypropylene Copolymers
Impact polypropylene copolymers (ICPs) are promising thermoplastics for recyclable high-voltage direct-current (HVDC) cable insulation, yet the links among molecular sequence, crystalline framework, multiphase topology, and charge transport remain unclear. A homopolymer-matrix…
Beijing University of Chemical TechnologyChina National Petroleum Corporation (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- INSULATION MATERIALS AND TECHNIQUES FOR HIGH-VOLTAGE DC POWER CABLES: RECENT DEVELOPMENTS, CHALLENGES AND FUTURE PERSPECTIVES.
Long-distance transmission of electrical energy is important for the integrationof international and national power grids. The use of high-voltage directcurrent (HVDC) cables enables the transmission of large electric powerquantities with limited energy losses and improves the…
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIalso at doi.org
- Analysis of Leakage Current Characteristics and Defect Fusion Diagnosis of Cable Water-Blocking Buffer Layers Under Multi-Frequency Excitation
The water-blocking buffer layer of high-voltage cross-linked polyethylene (XLPE) power cables is prone to degradation during long-term operation due to factors such as moisture and ablation. The degradation may cause an increase in leakage current, which is affected by frequency…
State Grid Corporation of China (China)North China Electric Power University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- RESEARCH INTO THE INFLUENCE OF HIGHER HARMONICS ON LEAKAGE CURRENTS AND DEGRADATION OF PAPER INSULATION IN HIGH-VOLTAGE CABLES
The article presents extensive experimental data on the operation of a 10 kV cable network at an industrial enterprise. The dielectric loss in paper insulation impregnated with a rosin-oil compound is analyzed. Insulation losses are determined using an analytical method and the…
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIalso at doi.org
- Pt- and Pd-Modified Two-Dimensional GeSe for Ethylene and Acetylene Sensing during Poly(vinyl chloride) Cable Overheating
Abstract Poly(vinyl chloride) (PVC) outer sheaths undergo pyrolysis during thermal faults or partial discharges in high-voltage cables, releasing marker gases such as ethylene (C2H4) and acetylene (C2H2). Developing sensing materials capable of sensitively identifying these gases…
Chongqing University of Science and Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Thermoreversible Diels-Alder networks enable high-temperature reliability in polypropylene HVDC cable insulation
Harbin University of Science and TechnologyHarbin University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Electromagnetic-Thermal-Fluid Coupled Analysis of High-Voltage Cables in Utility Tunnels with Temperature Distribution and Structural Comparison
State Grid Nanjing Power Supply Company (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Improving the High-Temperature Mechanical Properties and DC Electrical Properties of Polypropylene Insulation Materials through Grafting and Cross-Linking Modification
Abstract Thermoplastic polypropylene (PP) has been widely regarded as a promising alternative to cross-linked polyethylene (XLPE) for cable insulation owing to its excellent recyclability. However, PP exhibits poor mechanical toughness at room temperature, and blending with…
Harbin University of Science and TechnologyDalian University of Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Single-optical-path dual-mode speckle measurement method for noncontact vibration monitoring of gas-insulated switchgear
The mechanical state of gas-insulated switchgear (GIS) is often reflected by changes in vibration response, which require both reliable frequency readout and effective characterization of local response variations. We propose a single-optical-path dual-mode speckle measurement…
Hubei Provincial Water Resources and Hydropower Planning Survey and Design Institute
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- AMPLIFICATION OF ELECTROMECHANICAL STRESSES BETWEEN CLOSELY PLACED WATER MICRO-INCURRENTS IN THE INSULATION OF HIGH-VOLTAGE CABLES UNDER THE INFLUENCE OF AN ALTERNATING ELECTRIC FIELD
For crosslinked polyethylene insulation of high-voltage and ultra-high-voltage cables, a mathematical model of its electromechanical degradation near water micro-inclusions has been developed based on a combination of electrostatic and mechanical analysis. The finite element…
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”Institute of ElectrodynamicsKryvyi Rih National University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Incipient Weak Fault Detection in Cross-Bonded Cables Using Multichannel Sheath Currents
In high-voltage cable sheaths, incipient weak faults, such as jacket-damage grounding and high-resistance core–sheath breakdown, release little energy, rarely trigger protection, and can evolve into permanent faults. This study examines whether the topology-induced joint…
Fujian Electric Power Survey & Design InstituteState Grid Fujian Electric Power Company (China)Minjiang University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Study on mechanisms of moisture ingress and white spot growth in high-voltage cable buffer layers
A systematic study is conducted on mechanisms of moisture ingress and white spot growth in high-voltage XLPE (cross-linked polyethylene) cable buffer layers, aiming to clarify the sources of moisture and the evolution process of white spots. The moisture sources of the buffer…
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Comparative Effects of Al2O3 and SiO2 Nanofillers on the Thermal, Mechanical, and Electrical Properties of XLPE Cable Insulation
Al2O3 and SiO2 nanofillers have been widely used to improve the insulation performance of cross-linked polyethylene (XLPE) for high-voltage power cables. In this work, XLPE nanocomposites containing 3 wt.% Al2O3 or SiO2 were prepared to compare the effects of the two nanofillers…
Guangdong Power Grid Company (China)China Southern Power Grid (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Synergistic Modulation of Thermal Conductivity and Electrical Insulation in Polypropylene Composites via ( FeCoCrMnZn ) 3 O 4 High‐Entropy Oxide and α‐Zirconium Phosphate Hybrid Fillers
ABSTRACT The urgent demand for advanced electrical insulation materials with simultaneous high thermal conductivity and excellent electrical insulation has driven the development of high‐performance polymer composites. In this work, polypropylene (PP)‐based hybrid composites were…
Pingdingshan UniversityHenan University of Urban ConstructionHenan University of Technology
Applied / lab · Says "fabricated".From OpenAlex · not yet reviewedDOI
- The Effects and Mechanisms of Thermal Oxygen Aging on Trap Characteristics and Electrical Performance of Functional Group‐Grafted Materials for HVDC Cable Insulation
ABSTRACT In this study, N‐allylaniline (NA), a functional monomer possessing both deep trap‐inducing and antioxidant capabilities, was grafted onto cross‐linked polyethylene (XLPE) to prepare XLPE‐g‐NA. Both XLPE and XLPE‐g‐NA were subjected to thermo‐oxidative aging, and their…
Harbin University of Science and TechnologyHarbin Institute of TechnologyHarbin Engineering University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Polymeric materials for high-voltage insulation in power transmission systems: Advances, challenges, and future perspectives
Polymeric materials have been instrumental in present-day high-voltage (HV) electrical systems because of their high dielectric strength, light weight, design flexibility, and cost-effectiveness, which make them the basis for reliable and efficient energy transmission systems. As…
International University of Business Agriculture and Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Research on Typical Defect Electric Field and Temperature Characteristics of High Voltage Cable Terminal
During the installation of cable terminals, typical defects frequently occur due to construction practices. Defect types primarily include main insulation scratches, semiconductor tips, insulation layer impurities, and missing copper mesh. This study develops an electro-thermal…
Electric Power Research InstituteState Grid Corporation of China (China)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- A Method for Locating Insulation Defects in High-Voltage Cables Based on Double-End Recursive Identification
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Research on a Monitoring System for High-Voltage Cables in a Coal Mine Based on Intelligent Sensing Technology
Given the importance of monitoring the operational status of high-voltage cables in coal mines, this study investigates the application of intelligent sensing technology to the online monitoring of such cables. Taking an actual coal mine as a case study, a three-layer…
Fundamental research · No laboratory or pilot wording.From arXiv · not yet reviewedPDF
- Life Estimation of HVDC Cable Insulation under Load Cycles: from Macroscopic to Microscopic Charge Conduction Modelling
This paper goes one step forward in the life estimation of HVDC cable insulation under load cycles by introducing for the first time a microscopic model of charge conduction and transport i.e., Bipolar Charge Transport BCT model for electric field calculation inside the…
Fundamental research · No laboratory or pilot wording.From arXiv · not yet reviewedDOIPDF
- A Review of Polyolefin‐Insulation Materials in High Voltage Transmission; From Electronic Structures to Final Products
This review focuses on the use of polyolefins in high-voltage direct-current (HVDC) cables and capacitors. A short description of the latest evolution and current use of HVDC cables and capacitors is first provided, followed by the basics of electric insulation and capacitor…
Wallenberg Wood Science CenterKTH Royal Institute of TechnologyHitachi (Sweden)Hitachi in the directory6501 JPvia HitachiMid Sweden University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Transient Nonlinear Electrothermal Adjoint Sensitivity Analysis for HVDC Cable Joints
Efficient computation of sensitivities is a promising approach for efficiently of designing and optimizing high voltage direct current cable joints. This paper presents the adjoint variable method for coupled nonlinear transient electrothermal problems as an efficient approach to…
Fundamental research · No laboratory or pilot wording.From arXiv · not yet reviewedDOIPDF
- Intrinsic Current Concentration of Buffer Layer Material for Cable Ablation Failure: Role of Random Fiber Networks
In recent years, the buffer layer ablation failures of high voltage cables are frequently reported by the power systems. Previous studies have dominantly regarded the buffer layer as the continuous homogeneous medium, whereas neglects its microstructures. In this paper, the…
Fundamental research · No laboratory or pilot wording.From arXiv · not yet reviewedPDF
- DFT Study of Metal (Ag, Au, Pt)-Modified SnS 2 for Adsorption of SF 6 Decomposition Gases in Gas-Insulated Switchgear
In this study, the gas-sensitive response of metal (Ag, Au, Pt)-modified SnS 2 toward SF 6 decomposition gases (SOF 2, SO 2 F 2, SO 2, H 2 S) in gas-insulated switchgear was studied by analyzing the adsorption structure, band structure, charge transfer, and density of states…
Southwest UniversityState Grid Zhejiang Electric Power Company (China)Shanghai Electric (China)Chongqing University of Posts and Telecommunications
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Detection Method of Partial Discharge on Transformer and Gas-Insulated Switchgear: A Review
Detection of partial discharge (PD) activities in high-voltage equipment can be done according to the several mechanisms of signal detection, which are electromagnetic wave signal detection, acoustic signal detection, chemical reactions, electrical signal detection, or optical…
University of Technology MalaysiaMultimedia UniversityUniversiti Malaysia PerlisTun Hussein Onn University of Malaysia
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- SECURE - Securing the future delivery of all HVDC projects by de-risking the HVDC cable supply chain
Abstracts are not currently available in GtR for all funded research. This is normally because the abstract was not required at the time of proposal submission, but may be because it included sensitive information such as personal details.
Fundamental research · Research grant.From OpenAIRE (EU and national funders) · not yet reviewed
- Effect of charge transport on electrical degradation in polypropylene/organic molecular semiconductor composites for HVDC cable insulation
Polypropylene is considered to be the material of choice for environmentally friendly high voltage direct current cable insulation. The high power transmission of electrical energy exposes insulating materials to high temperatures and electric fields, resulting in the degradation…
Hunan UniversityTsinghua UniversityPennsylvania State University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Moisture Monitoring in Long-Range High-Voltage Cable Systems
Purpose and goal: We have evaluated the feasibility of developing and implementing fiber optic moisture measurement in power cables, as well as in joints and terminations. The fundamental requirements for this are met, and the study has provided insights into which applications…
Pilot / demonstration · Innovation or demonstration award.From OpenAIRE (EU and national funders) · not yet reviewed
- High voltage direct current transmission cables to help decarbonisation in Europe: Recent achievements and issues
Abstract High Voltage Direct Current (HVDC) underground and submarine cables constitute an essential technology for the long‐distance transmission of renewable electrical power with low losses, thereby fostering decarbonisation. In the past 2 decades, all this yielded a…
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Space Charge Measurement Equipment for Full-Scale HVDC Cables Using Electrically Insulating Polymeric Acoustic Coupler
A new, very sensitive device for space charge measurements on full-size cable is proposed. The measurement employs the basis of the pulsed electro-acoustic (PEA) method, in which an acoustic signal is produced due to the interaction between the pulsed electric field and the space…
Toyohashi University of TechnologyLS Cable & System (South Korea)
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Defect recognition and condition assessment of epoxy insulators in gas insulated switchgear based on multi-information fusion
Hubei University of Technology
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOI
- Evolution of Temperature Field around Underground Power Cable for Static and Cyclic Heating
Power transmission covering long-distances has shifted from overhead high voltage cables to underground power cable systems due to numerous failures under severe weather conditions and electromagnetic pollution. The underground power cable systems are limited by the melting point…
Christian-Albrechts-Universität zu KielKing Khalid University
Fundamental research · No laboratory or pilot wording.From OpenAlex · not yet reviewedDOIPDF
- Design improvements to cables and connectors in the Majorana Demonstrator
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched…
Fundamental research · No laboratory or pilot wording.From arXiv · not yet reviewedPDF